KYYH5WS-17/50

Metal Oxide Surge Arrester /Detachable type lightning arrester
Model: YH5WS-17/50
1.Current:65kA
2.Rated voltage:17KV
3.Certificate:ISO 9001.
4.OEM welcomed
5.Chinese National Standard

Metal-oxide surge arrester(Lightning arrster, polymer surge arrster)

Metal-oxide surge arrester(Lightning arrster, polymer surge arrster)

Surge arrester(Lightning arrster, polymer surge arrster)

Surge arrester(Lightning arrster, polymer surge arrster)

surge arrester(Lightning arrster, polymer surge arrster)

surge arrester(Lightning arrster, polymer surge arrster)

Surge arrester(Lightning arrster, polymer surge arrster)

Surge arrester(Lightning arrster, polymer surge arrster)

Surge arrester(Lightning arrster, polymer surge arrster)

Surge arrester(Lightning arrster, polymer surge arrster)

绝缘子主要技术参数Insulator Technical Parameters
型号 额定电压 额定机械负荷 结构高度 绝缘距离 爬电距离 雷电冲击耐受电压 工频耐受电压
Rated voltage Rated mechanical Structure height Insulationg distance creepage distance Lightning impuse P.F.wet withstand voltage
Type bending load withstand voltage
KV KN mm mm mm KV KV
FPQ-10/4 10 4 215 125 280 75 42
FPS-10/5 10 5 250 180 380 105 42
FZSW-35/6 35 6 450 360 946 185 95
FXBW-35/70 35 70 650 450 1015 230 95
FXBW-35/100 35 100 650 450 1015 230 95

Standards/Codes
Surge arresters are designed and tested per ANSI/IEEE C62.1, Standard for Gapped Silicone-Carbide Surge Arresters for AC Power Circuits, for the gapped type and ANSI/IEEE C62.11, Standard for Metal-Oxide Surge Arresters for Alternating Current Systems, for the gapless type. Article 280 of the NFPA70/National Electrical Code governs surge arrester’s general requirements, installation requirements and connection requirements. In addition, surge arresters are listed by UL under the category of, Surge Arresters (OWHX), and other NRTLs (Nationally Recognized Testing Laboratories) using the applicable sections of the ANSI/IEEE standards noted above.
Selection and Application
The primary objective in arrester application is to select the lowest rated surge arrester that will provide adequate protection of the equipment insulation and be rated such that it will have a satisfactory service life when connected to the power system. An arrester of the minimum practical rating is preferred because it provides the highest margin of protection for the equipment insulation system. There is a fine line between protection and service life of a surge arrester. Higher arrester ratings will increase the capability of the arrester to survive on a specific power system but reduce the margin of protection provided for the insulation level of the equipment it is protecting. Therefore, the reader should consider both issues of arrester survival and equipment protection when selecting surge arresters.

  • Download Excel FileTechnique-Insulators